Module efficiency reflects its ability to convert solar energy into electricity per unit of surface area. It is calculated using the following formula: Module Efficiency (η) = Pmax ÷ (Module Area × 1,000 W/m²) × 100%, where Pmax represents the maximum power output of the module.
In recent years, driven by the development of TOPCon, HJT and BC technologies, as well as continuous improvements in wafer dimensions and module design, module power output has increased from approximately 400W in earlier generations to more than 600W today.
However, an increase in module wattage does not necessarily indicate an improvement in conversion efficiency. At a similar cell conversion efficiency, increasing the module's overall surface area can also raise its total power output. Therefore, comparing modules solely based on their rated wattage does not provide a comprehensive assessment of their power output per unit area.
For C&I rooftop solar projects, the primary objectives of project owners are to reduce electricity costs and improve overall investment returns. Module selection therefore involves more than simply comparing initial procurement prices. Other important considerations include the self-consumption ratio, revenue from surplus electricity fed into the grid, project payback periods and long-term power generation performance.
In addition, rooftop conditions play an equally important role in determining project feasibility. Key factors include available installation area, building load-bearing capacity, roof structure, orientation and tilt angle, shading conditions, waterproofing requirements and the remaining service life of the building.
For older industrial facilities and colour-coated steel rooftops, particular attention must also be paid to structural safety and potential maintenance risks over the project's operating life.
A comparison of module specifications shows that rated power output and conversion efficiency are not necessarily positively correlated.
For example, Risen Energy's Hyper-ion Pro HJT module delivers a power output of 740W with a conversion efficiency of 23.8%. By comparison, Aiko's Comet 3N72 BC module has a lower rated power output of 675W but achieves a higher conversion efficiency of 25%.
The 740W module measures 2,384 × 1,303 mm, with a surface area of approximately 3.11 m², while the 675W module measures 2,382 × 1,134 mm, covering approximately 2.70 m².

The comparison shows that the 740W module has a surface area approximately 15.0% larger than that of the 675W module, while its rated power output is only 9.6% higher. Meanwhile, its conversion efficiency is 1.2 percentage points lower (23.8% versus 25%). This indicates that the higher power output of the 740W module is primarily attributable to its larger surface area rather than superior power conversion capability per unit area.
In terms of power output per unit area, the 740W module delivers approximately 238 W/m², compared with around 250 W/m² for the 675W module. In other words, under theoretical conditions involving the same rooftop area and equivalent layout utilisation, the 675W module could achieve approximately 4.9% higher installed capacity. Therefore, for C&I projects with limited rooftop space, installed capacity per unit area may be a more meaningful reference indicator than the rated wattage of an individual module.
Taking a 1MW installation requirement as an example, approximately 1,352 units of the 740W module would be required, covering a total module surface area of around 4,199 m². In comparison, approximately 1,482 units of the 675W module would be needed, with a total module surface area of approximately 4,003 m².
Although the 740W module reduces the required number of modules by approximately 8.8%, its total surface area is actually around 4.9% greater. This demonstrates that while higher-wattage modules can reduce the number of units required for installation, they do not necessarily improve rooftop space utilisation.
Furthermore, larger-format modules place additional requirements on mounting structures. The industry discussion surrounding the so-called "fish-farming module" issue in July primarily focused on oversized modules measuring 2,384 × 1,303 mm, corresponding to the 740W module examined in this article.
Modules of this size impose greater requirements on mounting structures, support span and mechanical load distribution. Under certain installation conditions, issues such as sagging in the middle of the module and water accumulation may occur, potentially increasing long-term reliability risks.
Therefore, module dimensions, installation tilt angles, support structures and mechanical load requirements must be properly matched. The actual advantages of high-wattage modules ultimately depend on the specific rooftop installation conditions.
In addition to rated power output and conversion efficiency, a module's actual power generation performance is also influenced by factors such as temperature coefficient, bifacial power generation capability, installation tilt angle, shading and local climatic conditions.
According to outdoor test results published in August 2026 covering 13 PV modules, the top eight performers in terms of specific energy yield (Wh/W) were all modules rated below 600W. Meanwhile, higher-wattage modules ranging from 625W to 710W did not make the top eight.

The test was conducted in Xi'an over the full 31 days of July, with cumulative solar irradiation reaching 212.77 kWh/m². During the testing period, daytime ambient temperatures ranged from 27.28°C to 34.48°C.
All modules were installed at an elevated height of 2 metres, with consistent installation tilt angles, orientations and electrical connection conditions. In terms of product configuration, the two BC modules adopted monofacial designs, while the remaining TOPCon and conventional P-type modules featured bifacial double-glass structures. The additional power generation from the rear side may therefore have influenced the final ranking in terms of specific energy yield.
Consequently, the test results reflect differences in both technology routes and module bifacial configurations. Actual power generation performance cannot be assessed solely based on module wattage or dimensions.
Under sustained high-temperature conditions, module dimensions and heat dissipation capabilities are also worth considering. For C&I rooftop projects where modules are installed relatively close to the roof surface, the limited ventilation space behind the modules creates different heat dissipation conditions compared with elevated mounting structures used in outdoor testing.
As a result, the high-temperature operating performance and temperature-related power losses of larger-format modules should also be taken into account during module selection.
Looking ahead, continued technological advancements will likely drive PV modules towards larger dimensions and higher conversion efficiencies. However, for rooftop solar projects, end-user selection is gradually moving away from a sole focus on higher module wattage towards a more comprehensive assessment of power output per unit area, actual power generation performance and compatibility with rooftop structures.
For C&I projects with limited rooftop resources, overall rooftop returns depend more heavily on the actual electricity generation achievable per unit of roof area. This can be assessed through a combination of module power density and specific energy yield per watt.
Based on the preceding module specification comparison and outdoor test results, larger-format modules have not demonstrated a clear advantage in either power output per unit area or specific energy yield. This further indicates that an increase in the rated power output of individual modules does not necessarily translate into higher electricity generation returns from rooftop installations.
Therefore, future module competitiveness will depend not only on improvements in individual module wattage, but also on the ability to deliver higher actual power generation within limited rooftop space, while maintaining installation compatibility and overall project economics.
Data Source Statement: Except for publicly available information, all other data are processed by SMM based on publicly available information, market communication, and relying on SMM's internal database model. They are for reference only and do not constitute decision-making recommendations.