Sizable Energy develops offshore storage system with 30-year-plus lifespan – ESS News

Sizable Energy is developing an offshore storage technology that uses ocean depth and gravity to store renewable energy and return it to the grid on demand. It works on a principle similar to pumped hydropower and is designed to pair floating solar with storage at sea, without lithium, land use or large onshore facilities.
The company has completed sea tests off Reggio Calabria, Italy, has received the STEP Seal from the European Commission’s Strategic Technologies for Europe Platform, and is preparing its first projects in Calabria and Sicily.
After raising $8 million, it is moving toward commercialization and is targeting an international market with more than 10 GWh of potential projects, co-founder Simone Biondi told pv magazine.
You raised $8 million last year to accelerate the path toward commercialization. What has happened over the past 12 months?
It was the year in which we closed the demonstration and conceptual phase and entered the project development phase. We completed sea tests in Reggio Calabria together with the Mediterranean University of Reggio Calabria, validating the behavior of key components under real conditions, following the tank testing campaign at Marin, and demonstrated that deployment operations can be completed without the use of special equipment. We received the European Commission’s STEP Seal, which recognizes the strategic value of the technology. On the industrial front, we secured additional resources for an integrated demonstrator with a data center in Naples, planned for the first half of 2027, and for the pre-FEED and FEED activities for the first project in Calabria and the second in Sicily. Finally, we built an international commercial pipeline, with more than 10 GWh of potential projects in the Mediterranean and Middle East, and advanced discussions in the Caribbean region.
Could you explain the solutions you are proposing?
Sizable Energy is developing a long-duration offshore gravity storage system. The principle is pumped hydropower, transferred to the sea: instead of freshwater and mountain elevation differences, we use high-density brine and ocean depth. When there is excess energy, the brine is pumped from a flexible reservoir on the seabed to a floating one at the surface; when energy is needed, it flows back down through a turbine. The system operates in a closed loop, consumes no land, uses common materials and does not degrade with cycling. We integrate it with floating solar and, in the Power Shell concept, with offshore data centers.
How do you see these solutions working with photovoltaics?
Photovoltaics is our natural partner. It produces a lot of energy at very low cost, but that production is concentrated in the middle of the day: the result is price cannibalization and a growing number of hours with zero or negative prices and curtailment. Long-duration storage makes it possible to shift that production toward the evening and night, turning photovoltaics into a dispatchable source. In addition, our offshore platform can host floating solar on the same area as the reservoirs, sharing infrastructure, moorings and the connection cable.
Who do you work with on research activities?
From the beginning, we have developed the technology together with academia, collaborating with the Mediterranean University of Reggio Calabria, the University of Modena and Reggio Emilia, the University of Padua, Politecnico di Milano, the University of Genoa and the Federico II University of Naples. Each has contributed to different aspects of the system, from hydrodynamics to structures, materials and machinery. In Reggio Calabria, at the Mediterranean University’s natural maritime engineering laboratory, we carried out the sea tests. On experimental validation, we have worked for a long time with Marin, the Dutch maritime research institute and one of the world’s leading organizations for offshore structure tank testing. Today, we have active collaborations with numerous industrial partners, who are accompanying us in the transition from research to the engineering of the first commercial projects.
What is the optimal sizing of the storage system relative to the capacity of the solar plant and consumption profiles?
There is no single ratio: it depends on what you want to achieve. In our architecture, power and energy are decoupled. Power increases with depth, because the number of machines that can be installed increases; energy depends on the volume of the reservoirs and the depth. We can therefore size the two parameters independently, according to the application. This is precisely where the value of long-duration storage becomes clear. A system lasting a few hours is essentially used to shift solar production toward the evening peak in demand and prices. With LDES (Long-Duration Energy Storage, ed.), much more can be done: covering all periods of high residual load, meaning when demand is not met by renewables. We are talking about cloudy days, periods of low wind generation or several consecutive days with little renewable generation. These are precisely the hours when the electricity system currently relies on gas, and when prices are highest. Long duration also opens up a new possibility: supplying constant loads with renewable energy, such as data centers, which consume electricity 24 hours a day, 365 days a year. In this case, the system must be sized to cover all hours without sunshine and guarantee continuity even during less favorable periods, an objective that is difficult to achieve economically with BESS.
What are the economic advantages of Sizable Energy storage compared with a PV system without storage?
With storage, energy is sold during the hours when prices are highest, the generation profile becomes dispatchable, and supply contracts of a baseload or near-baseload type can be signed, for example PPAs with large industrial consumers or data centers.
What are the advantages and disadvantages of Sizable Energy storage compared with a PV array with a battery energy storage system (BESS)? Could you elaborate on what you have already said?
Lithium BESS are an excellent technology, and we do not see them as direct competitors but as complementary. However, I would like to dispel a common misconception: that long-duration systems are only useful for shifting energy over time and cannot provide grid flexibility. That is not the case with our system. We respond with a speed comparable to batteries and can also provide grid inertia, real or synthetic depending on the configuration, a service that is increasingly valuable in an electricity system where conventional generation is giving way to renewables. For us, long duration means doing both things: time shifting on the one hand and ancillary services, reserve and balancing on the other, but for many more hours.
Our advantages emerge above all in GWh-scale plants: essentially, we are a pumped hydropower plant transferred to the sea. The cost of stored energy scales with the volume of the reservoirs and not with the number of cells, so adding storage hours costs relatively little. There is no degradation linked to cycling and the service life exceeds 30 years, compared with the typical 10–15 years for batteries. We use common materials, without dependence on critical raw materials or supply chains concentrated in Asia. There is no fire risk and no land consumption.
The disadvantages must be stated clearly. A site with seabed depths of at least 500 meters is required, at a reasonable distance from the coast and the grid. The solution makes sense only at utility scale, when considering GWh. And we are a first-of-a-kind technology. We use components and materials already employed in the offshore sector, and installation falls well within the capabilities and established operations of that industry. But integrating them into a new architecture still entails risks, which can only be overcome by demonstrating the system in the field. That is exactly what we are doing with the first projects, to build the track record needed for full commercialization.
For your solution, which applications offer the best economic returns: self-consumption, peak shaving, arbitrage or grid services?
For a system like ours, the answer is not one application but a combination of them. The basic value comes from renewable energy time shifting: moving large amounts of energy from hours of oversupply to periods of high residual load, which are not only evening hours but also days and periods of low renewable generation. Flexibility is added to this: ancillary services, reserve, balancing and inertia, which we can provide continuously and for many more hours than a short-duration system. It is this possibility of combining multiple revenue streams on the same asset that makes long duration economically interesting.
In Italy, the most suitable framework for grid-connected projects is Terna’s Macse, which offers long-term contracts for storage capacity and therefore revenue visibility, a decisive factor in financing infrastructure with a service life of more than 30 years. Among the applications we are exploring is also direct supply to large consumers with constant loads, such as data centers. A 24/7 renewable supply contract can have a higher value than energy sold on the spot market and guarantee stable cash flows over long periods. This is the idea behind our Power Shell concept, which integrates storage, floating solar and data centers on a single offshore platform.
Another natural synergy is with floating offshore wind, which is developed at precisely the depths suited to our system. Storage and the wind farm can share the export cable to shore. Instead of requiring a larger cable, storage makes it possible to size it according to average power rather than peak power: excess energy is stored at sea and fed into the grid when the cable has available capacity. This reduces connection costs, which weigh heavily in offshore projects, and avoids curtailment. Self-consumption and peak shaving, on the other hand, are smaller-scale applications, where BESS remain the natural choice.
What are the main metrics to consider when evaluating the return on investment (ROI) of solar plus storage?
For a solar-plus-storage system, the most representative metric is the levelized cost of energy (LCOE) of the combined system, meaning the levelized cost of the energy actually delivered, calculated over the entire service life of the generation plant and storage system together. The levelized cost of storage (LCOS), which measures the cost of the storage service alone, is useful for comparing storage technologies with one another, but it does not show how much the energy delivered to the customer or the grid costs. The key point is that not all LCOEs are comparable. The LCOE of a standalone solar plant is very low, but it describes energy available only during daylight hours. The correct comparison must be made on the basis of an equivalent service: how much does a renewable MWh cost when it is needed, including in the evening, at night or after days of low generation?
On this basis, long duration changes the numbers, because it makes it possible to cover many more hours with the same plant. Service life also matters: storage that lasts more than 30 years without degradation or replacements has a very different impact on LCOE from a system that must be repowered several times. Finally, from a financial perspective, infrastructure investors value the predictability of cash flows at least as much as the expected return. The share of contracted revenues, through Macse or long-term PPAs, compared with revenues exposed to the market is often what determines whether a project is financeable or not.
How would the storage system be integrated with inverters, energy management systems (EMS), and an existing PV plant?
Unlike a battery, our system is not electrochemical: the pumps and turbines are rotating electrical machines, connected to the grid through power converters, as in modern variable-speed pumped-storage plants, or directly as synchronous machines, depending on the configuration. In the first case, the system can provide synthetic inertia through grid-forming controls; in the second, physical inertia. From the grid and EMS perspective, the system behaves like a normal dispatchable storage asset, with charging and discharging setpoints, state of charge and operating constraints, and integrates into standard control systems through industrial protocols. In our projects, integration takes place at plant level: floating solar, storage and any associated load, such as a data center, share the substation and export cable to shore, reducing connection costs and times. Integration with an existing ground-mounted solar plant is possible in a co-located configuration, provided the site is close to the coast and to suitable seabed depths.
From pv magazine Italia
This content is protected by copyright and may not be reused. If you want to cooperate with us and would like to reuse some of our content, please contact: editors@pv-magazine.com.
Your email address will not be published. Required fields are marked *

This website uses cookies to anonymously count visitor numbers. View our privacy policy.
The cookie settings on this website are set to “allow cookies” to give you the best browsing experience possible. If you continue to use this website without changing your cookie settings or you click “Accept” below then you are consenting to this.
Close

source

This entry was posted in Renewables. Bookmark the permalink.

Leave a Reply